Implant relies on unique fastener to gear up for baby boomer generation

Written by  Spiralock July 20, 2011
As the first of the baby boomer generation turns 65 this year and promises to live longer and more actively than previous generations, implants and their components – including the fasteners that hold them together – must be built to last longer than ever before.
To handle the demands of tomorrow’s dynamic baby boomer population, for whom jogging, tennis and golf have been generational pursuits, some medical device companies are going beyond what’s currently required. For instance, some are specifying self locking fasteners in implants of the upper extremities that go way beyond 100,000 load cycles to withstand up to one-million load cycles without loosening or backing out.

When Skeletal Dynamics’ Align Radial Head System (above) is surgically installed, instrumentation allows alignment of the radial head as it would be in the patient’s native anatomy. Once the surgeon orients the device in this natural position, the surgeon tightens the set screw, a Spiralock milled interrupted thread to lock the device in the correct position.

“Patients are living longer and more vigorously than past generations, and that’s only going to increase as baby boomers demand more from their muscular-skeletal systems well past traditional ‘retirement age,’” said Tom Norman, vice president of Engineering at Miami, FL-based Skeletal Dynamics, a designer and marketer of innovative orthopedic devices.

To keep up with active baby boomers, Skeletal Dynamics (www.skeletaldynamics.com) recently developed its Align Radial Head System, an artificial elbow joint designed to restore the natural function of the native radial head.Previously, prosthetic radial head designs typically followed one of two approaches with significant drawbacks. While a traditional fixed monoblock design offered stability, it could not be aligned to the patient’s anatomy, which tended to wear away natural tissue such as cartilage. A bi-polar radial head was an attempt to align with the patient’s native anatomy, as it was able to rotate in a polyethylene sheath, but would not remain in the correct position because it would not lock.

“We aimed to fill a gap in the market by providing the ability to orient the joint to its natural position during surgery, and then locking it in place for the rest of the patient’s life,” said Norman. “We considered traditional fastener thread forms, but lacked confidence that they would stay in place for the up to a million load cycles an active patient could subject them to in their lifetime. Instead, we selected an innovative self locking fastener called Spiralock.”

Because repetitive loads, shock and loosening must be decisively handled for implant use, traditional fasteners susceptible to self-loosening rotational movement, stripping, and shearing are not always appropriate. Testing, in fact, has found that the first two threads of traditional fasteners can carry as much as 80% of the load, permitting stripping or shearing, while subsequent male threads “float” within the female threads.

spiralockfastenerswebAssorted Spirlock fasteners.

What makes Spiralock unique is its 30° “wedge” ramp cut at the root of the female thread (while traditional fasteners use a 60º thread). Under clamp load, the crests of the threads on any standard male bolt are drawn tightly against the wedge ramp. This not only eliminates sideways motion that causes vibrational loosening but also distributes the threaded joint’s load throughout all engaged threads, a claim supported by a Massachusetts Institute of Technology research study. The load percentage on the first engaged thread is significantly lower than traditional thread forms, which further reduces possible bolt failure and improves product performance.

When Skeletal Dynamics’ system is surgically installed in a patient, proprietary instrumentation allows alignment of the radial head as it would be in the patient’s native anatomy. Once the surgeon orients the device in this natural position, the surgeon tightens the set screw in a Spiralock milled interrupted thread made of cobalt chrome, against a long titanium stem designed for 3-point fixation, to lock the device in the correct position.

“While fasteners used in upper extremities are frequently tested to 100,000 cycles, third-party testing showed that the Spiralock self locking fastener used on the Align Radial Head successfully survived load and fatigue testing to one-million cycles without loosening or backing out,” said Norman. “That gave us the design confidence we needed, and helped with our FDA approval.”

This article was contributed by Spiralock.
www.spiralock.com

Add comment


Security code
Refresh

  • Digital Catalogues
    • Daemar Inc.
      Your online source for Shaft Seals, O-Rings, Retaining Rings, Bushings, Shaft Repair Sleeves, Shim, Keystock, Mechanical Seals, Braided Packing and Protective Closures.

Featured Videos

  • Hannover Messe 2012: Philip Harting interview Philip Harting, senior vice president of Harting Inc., spoke with DPN editorial director Mike Edwards at last week's Hannover Messe 2012. Harting spoke about the importance of the annual trade fair, the emergence of his company on the global stage, the need for corporate governance on carbon dioxide emissions and on Harting energy management technologies.